Open Circuit vs Short Circuit: Whats the Key Difference? Therefore, it shouldnt come as a surprise to learn that challenger is compatible with Eaton, cutler hammer, and square D. Westinghouse breakers are compatible with Cutler-Hammer. They use compatible ge circuit breakers to prevent damage from overcurrents and short circuits. What type of Breaker is on a GE tm1815e? What Size Extension Cord Do I Need for a 1500 Watt Heater? Breaker boxes have breakers that protect you by tripping in the event of an overload, shutting the power off. Table of Contents [ hide] Square D Homeline Compatible Breakers Guide to Finding Breakers Compatible with Square D 1. Siemens and Eaton both have Classified breakers that go into QO panels. By Minhazul Abedin July 11, 2022. The average contractor will encourage you to replace GE breakers with other GE breakers. The main breaker is 150 amps and there are 18 spaces for breakers. Eaton makes classified breakers that work in GE panels. Galvin Power is reader-supported. Square D QO breakers are compatible with QO breaker boxes and CSEDs. The Homeline breakers are made to fit in most interchangeable panels, such as GE, Bryant, Murray, ITE, etc. By Minhazul Abedin July 11, 2022. . They also get sold at Eaton stores throughout the country and specialty electrical outlets., You should also note that theres a possibility that you can swap out your Eaton or Cutler Hammer breaker with a Square D breaker. TM1815E model 3. Match the size and voltage requirements when using Siemens breakers, as using the wrong breakers can have dangerous results. I know CH are capable with many different brands, not sure about GE. Bryant is right up there with Challenger in terms of replacement difficulty. Moreover, you can use other breakers such as Square D Breakers, Westinghouse Breakers, Cutler hammer breakers, etc. I know that only breakers recommended by the panel manufacturer should be used. GE and Siemens circuit breakers are commonly known as a good match and interchangeable. Challenger replacements are difficult to find because the manufacturer stopped making the panels back in 1994. How Many Amps Does a Window AC Use? Match the size and voltage requirements when using Siemens breakers, as using the wrong breakers can have dangerous results. However, there are still a number of breaker-compatible brands that have high Bryant breaker compatibility. GE breakers are compatible with Cutler-Hammer, Eaton, Siemens, Murray, Challenger, & Westinghouse. Siemens breakers are almost always compatible with GE panel boxes as long as the model number on the GE breaker matches the one on the Siemens replacement., Outside of Siemens, a few select third-party companies make breakers compatible with GE. However, the UL Classified breaker cannot be used in GE panels. Homeline is Square Ds subtype, as discussed in the next section., There are restrictions on which Bryant and Challenger breakers are compatible with Square D. Additionally, although QO is another subtype of Square D, the two breakers are incompatible. WebYou have plenty of reasons to assume that GE and Eaton are compatible. Some breakers, such as bolt-in breakers, are not interchangeable with others; there are many different types of breakers to choose from. Manufacturers usually provide a list of brands in whose panels their breakers can work. These breakers are UL-listed and UL-classified. It appears to me that what you wanted was a Cutler-Hammer tandem breaker (Type BRD). Circuit breakers were one of their biggest products in years past, but production has steadily declined in recent decades. Siemens breakers can be used in GE breaker boxes, and they are generally known to be compatible. How do I determine if the ballast is the culprit when my HID lights wont turn on? If you ever face the issues, you know its a pathetic job to find out the compatible circuit breakers. (Detailed Answer). (Answered), Garage Door Only Closes When Holding Button? The most obvious choice is, without a doubt, Cutler-Hammer circuit breakers. Siemens breakers can be used in GE breaker boxes, and they are generally known to be compatible. If the wrong breaker is used it could fail to break (shut off power) during a surge. Super Easy Steps to Follow, How Do I Know if My HID Ballast is Bad? Most GE circuit breakers are compatible with the GE panels, but none go with them. All of the breakers in each panel were Cutler Hammer. You will also find some other breakers compatible with the ge panels. But you can pair GE panels with breakers from other brands if you can locate compatible options. Double-Pole Circuit Breaker with 921 reviews and the GE Q-Line 90 Amp 2 in. While Siemens breakers can be used in GE breaker boxes, not all GE breakers will function properly. Siemens breakers are compatible with GE breaker boxes and are commonly regarded as interchangeable. It's a specialty breaker that is available only at Eaton dealers. Does it resolve your issue with GE panel compatibility? Double Pole Circuit Breaker with 921 reviews. Siemens, of course, is the most well-known brand. Theyre also one of the longest discontinued brands, as they ceased operations in 1994. You must check the manufacturer requirements and the compatibility chart. Do you have an old one that you want to know if it still works? Siemens breakers can be used in GE breaker boxes, and they are generally known to be compatible. This video by Circuit Breaker Wholesale will also give you clarification about circuit breaker interchangeability. Cuttler-Hammer is also interchangeable with certain Square D breakers., The only way to know if breakers are interchangeable is by reading this article, matching up the model numbers on the different breakers, and checking for UL certification., While panel boxes and breakers often look similar, many are not interchangeable or compatible. Do you want to save money by extending your HID ballasts life? Yes, GE Circuit Breakers can be returned and have a 90-Day return period. Unfortunately, using the same brand isnt always possible, so youll have to work with what youve got. What Breakers are Compatible with Siemens? GE breakers will work in Cutler-Hammer panels, but you will need to use an adapter because they don't fit. Siemens breakers can be used in GE breaker boxes, and they are generally known to be compatible. Specified breakers are breakers that have been tested and listed for a panel by the manufacturer. Generally, the compatibility mainly depends on whether the panel is suitable for several breakers and can those breakers fit in them or not. GE breakers will work in Cutler-Hammer panels, but you will need to use an adapter because they don't fit. You must have the manufacturers clearance and check everything. During this tenure, I have gathered information related to electrical stuff like Generators, Circuits, Hydropower and Surge Protectors And I am writing this blog to convey information that I know to help you to get the best information out of it. In addition to everything else they produce, GE is a leader in panel boxes and circuit breakers. WebWhat breaker is compatible with Eaton BR? Therefore, you can use any breaker that is UL certified as an acceptable replacement to Siemens, as listed on your panel box. Match the size and voltage requirements when using Siemens breakers, as using the wrong breakers can have dangerous results. Specified breakers are breakers that have been tested and listed for a panel by the manufacturer. Square D is one of the more popular breaker brands available almost everywhere., If Siemens and Square D arent an option, you can also try Air Circuit Breakers, but only for voltage loads less than 450. WebIn short, Square D compatible breakers are Siemens, Cutler Hammer, Eaton, GE Breaker, Murray, Westinghouse, and Home Fitline. But many people have used GE and Eaton breakers in the same panel. You will also find some other breakers compatible with the ge panels. Check with your specific panel box before using another breaker in place of your Square Done., It should also be noted that, while these brands are okay for use in a Square D panel box, the feeling isnt always mutual. But compatibility is not guaranteed between every single Eaton and GE breaker. GE and Eaton breakers can fit in the same panel. What Is the Standard Height for Kitchen Counter Outlets? GE circuit breakers with catalog numbers ranging from THQL1115 through to THQL1150 can be substituted like for like with Cutler-Hammer circuit breakers coded CL115 through to CL150, ITE Siemens circuit breakers coded Q115 through to Q150 and Square D circuit breakers coded HOM115 through to HOM150. The ITE breakers are the same as the GE panels. Siemens breakers can be used in GE breaker boxes, and they are generally known to be compatible. Most GE circuit breakers are compatible with the GE panels, but none go with them. The power of connection is determined by the voltage of the desired utility in case of taking electrical connection in our home or commercial line. The Siemens, third party and Homeline circuit breakers are compatible with the GE panels. In that case, I highly suggest looking for a GE circuit breaker compatibility chart online to see the compatible replacement for your unit. GE is one of the most reputable and largest manufacturers of panel boards and circuit breakers. The breaker might fail to do its duty during electrical faults. Are GE and Eaton Breakers Interchangeable? However, if you dont have access to the brand itself, theres a very good chance that you can use UL classified breakers made These circuit breakers are used for overload and short-circuit protection of your electrical system. If it isnt an option, as it frequently isnt, then alternate options are acceptable as long as the model numbers match. However, suppose the label is not readable since it is too old. WebWhat breakers are compatible with GE THQL breakers? #1. The Siemens circuit breakers are compatible with the ge panels. False Eaton makes CHQ here is a square d panel from today CHQ is not listed as an acceptable breaker for square d because as you can see only square d breakers are not eaton. Match the size and voltage requirements when using Siemens breakers, as using the wrong breakers can have dangerous results. Fuses, Circuit Breakers & Safety Switches. Normally THQL is cheaper, but it's rather useful for early GE panels that THQL breakers are not compatible with. Can you rely on breakers from different brands? I love my job, and I have always wanted to offer others the necessary help so they can take care of their houses. Specified breakers are breakers that have been tested and listed for a panel by the manufacturer. Once this has been determined, you can use a breaker that fits the ge panel or use another breaker instead of that. Standard Step Height and Depth (Complete Guide), Standard Toilet Flange Height (Complete Guide). Similarly, the Eaton BR/CL breaker cannot be used in GE panels. Some manufacturers have models of breakers that will only fit specific types of panels. The homeline breakers are known to fit in the siemens panel, The third party or non-branded circuit breakers have some advantages. However, Siemens QD Series breakers are compatible with Square D load centers. Siemens breakers can be used in GE breaker boxes, and they are generally known to be compatible. These breakers are compatible with most Challenger panels and will provide the same level of protection as your original breaker. I just discovered the electrician who added c. 20 breakers (new circuits) to my GE panel used SqD HOM breakers last year. Purchasing the wrong breaker can result in a malfunction or even a burnt out breaker. Because of the similarities between different brands breakers, you can swap them out without fear of introducing an arc fault into your electrical system. The average contractor will encourage you to replace GE breakers with other GE breakers. Aug 9, 2017. Their breakers have unique mounting mechanisms that are only compatible with panels from the same brand. For the breaker type, you need to be specific about whether you need a GFCI, AFCI, combination AFCI, or Dual Function Circuit Interrupter. GE breakers will work in Cutler-Hammer panels, but you will need to use an adapter because they don't fit. WebIn short, Square D compatible breakers are Siemens, Cutler Hammer, Eaton, GE Breaker, Murray, Westinghouse, and Home Fitline. Will Siemens breaker fit GE panel? These are two entirely different type of circuit breaker. Did you find this article helpful? But you can pair GE panels with breakers from other brands if you can locate compatible options. Table of Contents [ hide] Square D Homeline Compatible Breakers Guide to Finding Breakers Compatible with Square D 1. Eatons UL classified breakers are designed and tested to be both mechanically and electrically interchangeable with circuit breakers manufactured by General Electric, Thomas & Betts, ITE/Siemens, Murray, Crouse-Hinds, and Can GE Circuit Breakers be returned? Replacing a panel box is expensive work, so you should locate an acceptable replacement for the breaker if possible unless the box presents a safety hazard., Weve all heard of General Electric and likely have at least one appliance or electrical device made by the company. Match the size and voltage requirements when using Siemens breakers, as using the wrong breakers can have dangerous results. What type of Breaker is on a GE tm1815e? However, there are still a number of breaker-compatible brands that have high Bryant breaker compatibility. As a result, there are usually at least one or two circuit breaker brands interchangeable with other breakers. Learn more, Written byEdwin Jones/ Fact checked byAndrew Wright. However, Square D added a small protrusion on their bus bars to reject those other breakers from being installed in Before making a swap, however, there are certain things you should check for regardless of what this list or any other might tell you., The first thing you should look at is the size of the breaker youre replacing. Siemens does make classified breakers. The Homeline breakers are made to fit in most interchangeable panels, such as GE, Bryant, Murray, ITE, etc. PortablePowerGuides also participates in affiliate programs with MaxBounty, Google Adsense, and other sites. If you have a challenger panel, you will probably look for breakers from different brands once your challenger breakers malfunction. Siemens breakers can be used in GE breaker boxes, and they are generally known to be compatible. You can only decide if you can interchange or use them on the GE panels. So, who do you think is the best manufacturer for the job? What circuit breakers are compatible with ge panels? Square D Homeline breakers are compatible with Homeline breaker boxes and CSEDs. I know Seimens makes one for Sq.D, etc Jraef Moderator Staff member Location San Francisco Bay Area, CA, USA Occupation Electrical Engineer Aug 22, 2012 #3 You cannot approach it from the GE panel side, their answer will always be the same: GE. Sometimes, it is twice the price of third party products. After all, GE is interchangeable with brands like Siemens that work with Eaton breakers and panels. WebThey are also compatible with Square D breakers. Eaton owns Cutler-Hammer, so they make sure their products are interchangeable. Some manufacturers wont give you a choice in the matter. We are a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for us to earn fees by linking to Amazon.com and affiliated sites. You will find many non branded circuit breakers that can be used on the GE panels, but they are not secure and can harm your device or appliances. One of the most significant benefits of using Siemens QT breakers is that they're easy to install because they're designed to I know that only breakers recommended by the panel manufacturer should be used. #1. Siemens does make classified breakers. Share Improve this answer Follow answered Jan 19, 2022 at 20:41 In other words, if you have a GE electrical box, it is also good to use a GE circuit breaker. So, who do you think is the best manufacturer for the job? Then, it will become a challenge to get a perfect substitute instead of the original. However, just be mindful about your needed circuit breaker rating when utilizing either of these brands to replace the other. These are UL-CLassified for certain specific competitor panel lines, and overrides the label. At the end of the day, its Cutler-Hammer Breaker that bought out Bryant. But you should check the cutler hammer manual to see if the manufacturer thinks that Cutler-Hammer and GE are compatible. While these other breakers will work, theres a good chance they will violate your local building code or void the warranty on your panel box., Eaton is another mega-company thats been a pillar in the world of electrical devices for decades. Go to the hardware shop and buy the Siemen and install it accordingly. GE and Siemens circuit breakers are commonly known as a good match and interchangeable. Match the size and voltage requirements when using Siemens breakers, as using the wrong breakers can have dangerous results. Hard Water Calcium Buildup in Pipes: How to Fix? Now, Siemens' website just burned down so Google is useless (every page is 404). That hasnt stopped people from using square D breakers in GE panels. The Bryant breakers are not compatible with the GE panels. All of the breakers in each panel were Cutler Hammer. You will also find some other breakers compatible with the ge panels. And by keeping the desired voltage unchanged, we can easily use another breaker instead of a circuit breaker of the same feature on that ge panel. But compatibility is not guaranteed between every single Eaton and GE breaker. Floating Shelf Height: How High Should a Floating Shelf Be? You can alter them or use them safely on the GE panels. However, you cannot use all the circuit breakers with the ge panels; there are some power differences between them. It is essential to understand its load, and a critical feature that drives them is the rated current. For instance, Siemens 1 and 2 wide breakers are not compatible with Square D panels. These are UL-CLassified for certain specific competitor panel lines, and overrides the label. WebAs a result, Westinghouse circuit breakers work with Cutler-Hammer, Eaton, and Square D breakers. WebWhat breaker is compatible with Eaton BR? For the most part, as long as the model numbers match up, Square D is compatible with other major brands such as Siemens, Cutler-Hammer, Eaton, GE, Murray, Homeline, and Westinghouse. Knowing the rated current is a significant criterion in selecting a circuit breaker for an electrical connection. Can GE Circuit Breakers be returned? Square D is the first brand I would recommend, thanks to its sturdy construction, reliability, and ease of working with. It should have labeling that shows the breakers that can work with the panel. You should note that even if you can find a replacement breaker with the Challenger brand, it may not be the best option for you. It would be helpful to know what breakers are compatible with GE panel. However, there are still a number of breaker-compatible brands that have high Bryant breaker compatibility. What Breakers are Compatible with Cutler-Hammer? You will also find some other breakers compatible with the ge panels. False Eaton makes CHQ here is a square d panel from today CHQ is not listed as an acceptable breaker for square d because as you can see only square d breakers are not eaton. Square D Siemens, of course, is the most well-known brand. But whether they are compatible perfectly with one another is a big concern. It is strongly advised that the incorrect breakers never be utilized in any situation. ccurrins (Christopher Currins, CMI) September 25, 2015, 1:49am #1. WebAs a result, Westinghouse circuit breakers work with Cutler-Hammer, Eaton, and Square D breakers. Every house has breaker boxes that control the volume of current your home uses. You only need to know if your box can support these units. As we have mentioned, Bryant is now officially out of the breaker business. The original breakers (10 years ago) are GE and fine. In short, Square D compatible breakers are Siemens, Cutler Hammer, Eaton, GE Breaker, Murray, Westinghouse, and Home Fitline. When utilizing Siemens breakers, make sure that the size and voltage requirements are met, as using the incorrect breakers can result in dangerous consequences. So, you need to check everything before installing on your GE panels. He has an unconventional approach to problem-solving, and is adept at devising original solutions to complex issues. Eaton breakers are almost all compatible with Cutler-Hammer panels. WebThereof, what breakers are compatible with Square D Homeline? We need to rely on some parameters to use another breaker instead of one that fits your ge panel. Some brands have bought out other brands, which means their breakers are compatible. This is the mistake people make. link to Can You Leave Doorbell Wires Exposed? (no pun intended). If the wrong breaker is used it could fail to break (shut off power) during a surge. Each GE breaker model with a specific amp and voltage rating has an equivalent model in the Eaton brand. You must know which breakers are interchangeable, not just in appearance but also in functionality., Whenever possible, you should always stick with breakers of the same brand when switching out an old one for a new one. The most obvious choice is, without a doubt, Cutler-Hammer circuit breakers. 40, 50 And 60 Amp Double Pulls. 4 Easy Steps. Is a GE THQL 2115 15A 2 P Breaker Interchangeable with a Cutler Hammer BRD&A 15 amp double breaker? All of the breakers in each panel were Cutler Hammer. In addition to Murray, Siemens has several breaker subtypes that are often compatible with traditional Siemens breakers. Are Siemens and GE Breakers Interchangeable? Square D Homeline Compatible Breakers. WebThe Siemens circuit breakers are compatible with the ge panels. What are 20 amp breakers used for? Siemens, of course, is the most well-known brand. Still, you should check the rating and get clearance from the manufacturer. Ensure that the correct brand of breakers is installed in your breaker panel. However, when the latter becomes obsolete or old, theres a chance that it may be unavailable where you live. Feb 10, 2014. rewire said: They are listed as replacement breakers so they are compliant. However, just be mindful about your needed circuit breaker rating when utilizing either of these brands to replace the other. If Underwriters Laboratories has said that a particular GE breaker can work in your Murray Panel, you can interchange those GE and Murray breakers. However, Square D added a small protrusion on their bus bars to reject those other breakers from being installed in Stellar is an engineer. What Gauge Extension Cord for a Space Heater? As an Amazon Associate I earn from qualifying purchases. We have an affiliate partnership with Networx, Reasons You Might Need to Use a Different Breaker, What to Look for When Interchanging Breakers. Share Improve this answer Follow answered Jan 19, 2022 at 20:41 Similarly, the Eaton BR/CL breaker cannot be used in GE panels. The answer is also yes. There are many brands that make a UL listed breaker for other brand panels. Is a GE THQL 2115 15A 2 P Breaker Interchangeable with a Cutler Hammer BRD&A 15 amp double breaker? Siemens breakers can be used in GE breaker boxes, and they are generally known to be compatible. Another big reason that Eaton is compatible with numerous breakers is that the company that owns the production rights for Eaton breakers owns the same rights for various companies.Breaker BrandInterchangeable with EatonExactly the Same as EatonWestinghouseYesYesSquare DYesYesCutler-HammerYesYesGEYesNoThomas & BettsYesNoITE/SiemensYesNoMurrayYesNoCrouse-HindsYesNo, Because Eaton is interchangeable with so many different circuit breakers, its common for electricians to install Eaton panel boxes in new homes. However, dont assume that every GE breaker works in every GE panel. Therefore, you can trust them to make the best breakers for their panels. Though i have a ge box, this siemens breaker is compatible with this panel. How Much Does It Cost to Install a 240v Outlet in Garage? Circuit breakers are identified by markings stamped on the side of the device, and they are often found inside the cover door of the panel. Lets see if they all are compatible with the GE panels. Amazon, the Amazon logo, AmazonSupply, and the AmazonSupply logo are trademarks of Amazon.com, Inc. or its affiliates. You cannot always use the same circuit breaker over and over. For this reason, Cutler-Hammer circuit breakers arent always readily available in all parts of the country., Its probably a good thing then that Eaton bought out Cutler-Hammer in 1978. Siemens and Eaton both have Classified breakers that go into QO panels. Today a five year old well built home with two GE panels, GE main breaker (s). Which breakers are interchangeable? Siemens breakers can be used in GE breaker boxes, and they are generally known to be compatible. However, some discourage the use of Eaton breakers in GE panels because GE panels are not included in the list of brands with whom Eaton breakers can work. One of the most positive sides of them is the cost. GE and a few other brands will not fit into other panels due to their physical size for plug-in breakers. The average contractor will encourage you to replace GE breakers with other GE breakers. Ge breakers. Knowing those parameters, we can replace them according to the character of the breaker. While you likely wont have trouble finding a Homeline breaker to replace your old one, its very inconvenient if you do., Thousands, if not millions, of older homes throughout the US, operate with Westinghouse panel boxes. In those case, you should replace the entire panel. 2). 1). What Breakers are Compatible with Westinghouse? Square D QO breakers are compatible with QO breaker boxes and CSEDs. Siemens breakers can be used in GE breaker boxes, and they are generally known to be compatible. When setting up these fixtures, it is common to use an extension cord , Extension cords can provide power to appliances when outlets are too far away. After all, they went out of business mainly because of faulty breakers. If this question enters your mind, you may want to install a new circuit or upgrade an old circuit. The documentation square D has released thus far doesnt encourage anyone to use their breakers in panels from other brands. The label in the service panel identifies the panel as GE cat.no. What are 20 amp breakers used for? The main breaker is 150 amps and there are 18 spaces for breakers. But you can pair GE panels with breakers from other brands if you can locate compatible options. One of them is to look for the label inside your electrical panel. You must know your panel boxs brand and which circuit breakers are compatible with them if you dont have easy access to an exact replacement., Consult a professional electrician if youre ever in doubt or questioning compatibility. You can interchange them and use them securely. One of the most significant benefits of using Siemens QT breakers is that they're easy to install because they're designed to Do I need , Do you often buy HID ballasts? The Square D breakers are not compatible with the GE panels. Are Siemens and Cutler-Hammer breakers interchangeable? What you were sold is a GE 2 pole breaker. It's a specialty breaker that is available only at Eaton dealers. Power Strip Keeps Turning Off Causes & Solutions. Do you want to know when to repair and when to buy , Whether youre new or a veteran in creating stained glass art, we know that a stained glass soldering iron is one of the hardest things to buy due to its , Whether youre a pro or just a casual hobbyist, investing in your work by having the best soldering station for electronics, DIY repairs, and the like makes a lot of , Did you install electrical boxes for a new set of circuit series? The same thing happens with GE breakers. . The average contractor will encourage you to replace GE breakers with other GE breakers. The Breaker Must Be Similar To The Original Design. However, most Murray products were phased out in 2019, so you might be out of luck finding a Murray circuit breaker., If you cant find a Murray circuit breaker, your best bet is to use a breaker from the company that bought them out, Siemens. This way, you can safely use other brands of circuit protectors in case GE breakers are not available at your nearest store. However, if you dont have access to the brand itself, theres a very good chance that you can use UL classified breakers made